Hot Work, Welding & Torch Cutting JHA Template (OSHA 1926 Subpart J)
Hot work JHA covering combustible clearance/welding blankets, immediate fire extinguisher access, post-work fire watch, galvanized/coated fume ventilation, and shaded welding lenses.
Includes Word (.docx), Excel (.xlsx), and PDF · Need just this JHA?
Draft for competent-person review: Walk the jobsite, adjust controls for actual conditions, and sign before work starts. Covers US federal 29 CFR Part 1926 only (state-plan states like CA, WA, and OR enforce extra rules). Not an OSHA compliance guarantee.
Steps, hazards & controls
| Work Step | Hazard | Control | 29 CFR 1926 Reference |
|---|---|---|---|
| Clear combustibles, stage extinguisher, and set fire shields | Jobsite fire from welding slag, sparks, or torch heat | Move work or relocate all movable combustibles out of the spark radius before lighting up Control level: elimination | |
| Clear combustibles, stage extinguisher, and set fire shields | Jobsite fire from welding slag, sparks, or torch heat | Cover immovable combustibles and floor penetrations with fire-resistant welding blankets/guards Control level: engineering | |
| Clear combustibles, stage extinguisher, and set fire shields | Jobsite fire from welding slag, sparks, or torch heat | Stage a charged, inspected ABC fire extinguisher immediately at the hot work station Control level: engineering | |
| Perform welding/cutting and maintain post-work fire watch | Arc flash eye injury, toxic welding fumes (zinc/lead coatings), and smoldering fires after shift | Use filter lenses with appropriate shade number for welding/torch process and install welding screens for nearby crew Control level: ppe | |
| Perform welding/cutting and maintain post-work fire watch | Arc flash eye injury, toxic welding fumes (zinc/lead coatings), and smoldering fires after shift | Provide local mechanical exhaust ventilation (and respiratory protection if welding galvanized/coated metals or enclosed spaces) Control level: engineering | |
| Perform welding/cutting and maintain post-work fire watch | Arc flash eye injury, toxic welding fumes (zinc/lead coatings), and smoldering fires after shift | Maintain dedicated fire watch during hot work and for required post-work monitoring period Control level: administrative |
Competent person & paperwork
Competent person required: Confirm by site conditions
Assign a trained fire watch whenever sparks or slag can reach combustibles (1926.352(e)).
- Site Hot Work Permit & Fire Watch Log (when required by GC/owner)