OSHA 29 CFR 1926 Subpart J · Checked Nov 26, 2026

Hot Work, Welding & Torch Cutting JHA Template (OSHA 1926 Subpart J)

Hot work JHA covering combustible clearance/welding blankets, immediate fire extinguisher access, post-work fire watch, galvanized/coated fume ventilation, and shaded welding lenses.

Draft a JHA for Your Task (Free)

Includes Word (.docx), Excel (.xlsx), and PDF · Need just this JHA?

Draft for competent-person review: Walk the jobsite, adjust controls for actual conditions, and sign before work starts. Covers US federal 29 CFR Part 1926 only (state-plan states like CA, WA, and OR enforce extra rules). Not an OSHA compliance guarantee.

Steps, hazards & controls

Work Step Hazard Control 29 CFR 1926 Reference
Clear combustibles, stage extinguisher, and set fire shields Jobsite fire from welding slag, sparks, or torch heat Move work or relocate all movable combustibles out of the spark radius before lighting up
Control level: elimination
Clear combustibles, stage extinguisher, and set fire shields Jobsite fire from welding slag, sparks, or torch heat Cover immovable combustibles and floor penetrations with fire-resistant welding blankets/guards
Control level: engineering
Clear combustibles, stage extinguisher, and set fire shields Jobsite fire from welding slag, sparks, or torch heat Stage a charged, inspected ABC fire extinguisher immediately at the hot work station
Control level: engineering
Perform welding/cutting and maintain post-work fire watch Arc flash eye injury, toxic welding fumes (zinc/lead coatings), and smoldering fires after shift Use filter lenses with appropriate shade number for welding/torch process and install welding screens for nearby crew
Control level: ppe
Perform welding/cutting and maintain post-work fire watch Arc flash eye injury, toxic welding fumes (zinc/lead coatings), and smoldering fires after shift Provide local mechanical exhaust ventilation (and respiratory protection if welding galvanized/coated metals or enclosed spaces)
Control level: engineering
Perform welding/cutting and maintain post-work fire watch Arc flash eye injury, toxic welding fumes (zinc/lead coatings), and smoldering fires after shift Maintain dedicated fire watch during hot work and for required post-work monitoring period
Control level: administrative

Competent person & paperwork

Competent person required: Confirm by site conditions

Assign a trained fire watch whenever sparks or slag can reach combustibles (1926.352(e)).

  • Site Hot Work Permit & Fire Watch Log (when required by GC/owner)

Baseline PPE

  • Welding hood / cutting goggles with proper ANSI filter shade
  • Flame-resistant (FR) jacket/sleeves
  • Leather welding gloves
  • Respirator when welding coated/galvanized steel
Related OSHA 1926 guides: 1926.352 · 1926.353 · 1926.102