OSHA 29 CFR 1926 Subpart Z · Checked Nov 26, 2026

Concrete Saw-Cutting & Silica Exposure JHA Template (29 CFR 1926.1153)

Silica JHA built around 29 CFR 1926.1153 Table 1 wet-cutting and HEPA vacuum controls, prohibition of dry sweeping, written Exposure Control Plan, and competent-person oversight.

Draft a JHA for Your Task (Free)

Includes Word (.docx), Excel (.xlsx), and PDF · Need just this JHA?

Draft for competent-person review: Walk the jobsite, adjust controls for actual conditions, and sign before work starts. Covers US federal 29 CFR Part 1926 only (state-plan states like CA, WA, and OR enforce extra rules). Not an OSHA compliance guarantee.

Steps, hazards & controls

Work Step Hazard Control 29 CFR 1926 Reference
Stage wet-cut / HEPA shroud controls and restrict access zone Inhalation of respirable crystalline silica dust by operator or bystanders Implement 1926.1153 Table 1 integrated water-delivery system (or HEPA shroud vacuum with filter-cleaning mechanism) continuously during cutting
Control level: engineering
Stage wet-cut / HEPA shroud controls and restrict access zone Inhalation of respirable crystalline silica dust by operator or bystanders Follow written Silica Exposure Control Plan and barricade work area to restrict non-essential workers
Control level: administrative
Stage wet-cut / HEPA shroud controls and restrict access zone Inhalation of respirable crystalline silica dust by operator or bystanders Designated competent person verifies water flow, blade guard, and required respirator APF before cutting begins
Control level: administrative
Cut concrete/masonry and clean up slurry/debris Flying concrete chips/kickback and re-aerosolized silica dust during cleanup Wear ANSI Z87.1 impact eyewear with side shields and full face shield during saw operation
Control level: ppe
Cut concrete/masonry and clean up slurry/debris Flying concrete chips/kickback and re-aerosolized silica dust during cleanup Prohibit dry sweeping or compressed-air blowdown; clean up wet slurry or use HEPA-filtered vacuum only
Control level: engineering

Competent person & paperwork

Competent person required: Yes

Employer must designate a competent person to conduct frequent inspections implementing the Written Silica Exposure Control Plan (1926.1153(g)(4)).

  • Written Silica Exposure Control Plan (29 CFR 1926.1153(g)(1))
  • Respirator medical clearance & fit test if Table 1 requires APF 10+

Baseline PPE

  • NIOSH-approved N95/P100 respirator per Table 1 duration/indoor rules
  • ANSI Z87.1 safety glasses + face shield
  • Hearing protection
  • Waterproof boots & gloves
Related OSHA 1926 guides: 1926.1153 · 1926.102