Paperwork for 29 CFR 1926.502: Fall protection systems criteria and practices.
Plain-English summary (not the official rule): Sets design and inspection criteria for guardrails (42 in ± 3 in toprail, 200 lb force), PFAS anchorages (5,000 lb per attached employee or qualified-person 2x safety factor), hole covers (2x load, secured, marked "HOLE"/"COVER"), and pre-use harness inspection.
Written records & field paperwork
| Citation | Document / Record | What to include |
|---|---|---|
| 29 CFR 1926.502(d)(21) | Daily PFAS harness/lanyard/anchor inspection check | Inspect personal fall arrest systems prior to each use for wear, damage, and deterioration; remove defective components. |
| 29 CFR 1926.502(d)(20) | Prompt rescue plan documented on JHA | Provide for prompt rescue of employees in the event of a fall or assure employees can rescue themselves. |
Key paragraphs referenced
| Paragraph | Summary |
|---|---|
| 1926.502(b)(1) | Top edge height of top rails must be 42 inches plus or minus 3 inches above the walking/working level. |
| 1926.502(d)(15) | Anchorages used for attachment of personal fall arrest equipment must support at least 5,000 pounds per employee attached, or be designed/installed under a qualified person maintaining a safety factor of at least two. |
| 1926.502(d)(20) | Employer must provide for prompt rescue of employees in the event of a fall or assure employees are able to rescue themselves. |
| 1926.502(d)(21) | Personal fall arrest systems must be inspected prior to each use for wear, damage, and other deterioration; defective components removed from service. |
| 1926.502(i)(2) | Covers for floor/roof holes must support at least twice the weight of employees, equipment, and materials, be secured against accidental displacement, and be color coded or marked "HOLE" or "COVER". |